conservationstrategies.com
  • Cart

 Shop By

  • Specials
  • Alarms
  • Blower Doors, DuctBlasters & Airflow

    Blower Doors, DuctBlasters & Airflow

    • Blower Doors & Accessories
    • Duct Blaster® System & Accessories
    • Commercial/Multi-fan Blower Door equipment
    • Balometers/Air Flow Hoods
    • Smoke Puffers
    • Vent Covers/Duct Mask
    • Flow Meters
    • Digital Pressure Gauges
    • TECTrainer
    • Duct Mask
  • Caulks & Sealants
  • Diagnostics

    Diagnostics

    • Air Flow & Velocity
    • Combustion Analyzers
    • Gas Leak Detectors
    • Personal CO Meters
    • Power Detectors & Analyzers
    • Pressure Measurement
    • Temperature/Moisture/Humidity Meters
    • Accessories/Parts
  • Duct Leakage Testing
  • Foams
  • Accessories
  • Kits

    Kits

    • Residential Energy Conservation Kits
    • Kits for the Energy Professional
  • Lighting
  • Mobile Home Parts
  • Plugs
  • Safety & Protective

    Safety & Protective

    • Respirators & Breathing Protection
    • Lead Check
    • Eye Protection
    • Gloves
    • First Aid Kits
    • Stay Cool!
    • ZipWall
  • Smoke Puffers & Machines
  • Tools & Useful Stuff

    Tools & Useful Stuff

    • Tools & Useful Stuff
  • Weather-proofing
  • Bacharach
  • Testo

    Testo

    • Airflow & Velocity
    • Combustion Analyzation & Gas Leakage
    • Pressure
    • Temperature/Moisture/Humidity
    • Thermal Imagers
    • Accessories/Parts
  • The Energy Conservatory

    The Energy Conservatory

    • Blower Door Systems & Accessories
    • Blower Door Replacement Parts
    • Duct Blaster® System & Accessories
    • Duct Blaster® Replacement Parts
    • Digital Pressure Gauges
    • Exhaust Fan Flow Meter
    • TrueFlow® Air Handler Flow Meter
    • Commercial/Multi-fan Blower Door equipment
  • Energy Auditing Services

    Energy Auditing Services

    • Single-Family Residential Energy Audits
    • Multi-Family Energy Services
  • Login
  • My Account
  • View Cart
  • About Us - Contact Us
  • Brands
  • Energy Audits
  • Resources
  • Apply for Credit!
Specifications for the APT System and Accessories



No Products found



The Automated Performance Testing (APT) System defines the state-of-the-art in building diagnostics by combining computerized control of the Minneapolis Blower Door system with multi-channel pressure measurement and data logging capabilities. The APT system is operated from a user supplied laptop computer using custom software developed by The Energy Conservatory. During an automated airtightness test, the APT system adjusts the speed of the Blower Door fan while simultaneously monitoring and recording the building pressures and fan flow rates. The APT can be configured to record pressures from attached building zones (attics, garages etc.) during the Blower Door test to help diagnose complex air leakage paths. Blower Door test results are recorded, displayed on the screen and can be saved to a file.

When used with our TECLOG data logging software, the APT system becomes a powerful data logging system with up to 8 high resolution pressure channels and 8 analog voltage input channels (which can be connected to optional temperature, relative humidity and carbon monoxide sensors). The APT system allows you to simultaneously monitor and record the interaction of building pressures along with other performance variables (e.g. temperature, relative humidity) over time.

APT System Specifications

Data Box Specifications
Inputs:
Pressure: 2 differential pressure channels with auto-zeroing (APT-2). 3 to 8 differential pressure channels with auto-zeroing (APT-8). Switchable resolution of 0.1 Pa and 0.5 (Pa), with corresponding ranges of approximately +/-400 Pa and +/- 1,000 Pa, respectively.
Voltage: 8 differential analog DC voltage input channels. Switchable resolution of 0.1 mV and 1 mV, with corresponding ranges of approximately +/-400 mV and +/-4 V, respectively. Voltage channels are accessed via a bank of 8 six-contact phone jacks. Continuous 5V (regulated,+/-1%, max 50 mA) power available for optional sensors.
Outputs: Automated fan speed control connection to Minneapolis Blower Door and Duct Blaster systems.
2 switchable digital outputs (5V regulated).
Communication: RS-232 connector (9-pin) to interface to your PC at 9,600 baud.
Power: Internal NiCd battery pack with AC power adapter.
Accuracy:
Pressure: +/- 1% of reading, or 2 x resolution, whichever is greater from 0-800 Pa (at 10 °C to 30 °C). +/- 2% of reading from 800-1,000 Pa.
Voltage: +/- 0.1% of reading, or 2 x resolution, whichever is greater from 0-4 Volts (at 10 °C to 30 °C).
Dimensions: 4"x 8" x 1.5" (APT-2). 4" x 10"x 3" (APT-8).

Temperature Sensor
Sensing Method: Precision NTC Thermistor, 10k Ohms @ 25 °C.
Accuracy: +/- 0.25 °C (0 to 75 °C),
+/- 0.5 °C (<0 °C, >75 °C).
Range: -40 °C to 100 °C (-40 °F to 212 °F).
Resolution: 0.025 °C (0.045 °F) @ -40 °C (-40 °F).
0.05 °C (0.09 °F) @ 21 °C (70 °F).
1.0 °C (1.8 °F) @ 100 °C (212 °F).
Time Constant: 11 seconds in slowly moving air, 70 seconds in still air.
Operating Temperature: -40 °C to 100 °C (-40 °F to 212 °F).
Storage Temperature: -40 °C to 100 °C (-40 °F to 212 °F).
Current Draw: 11 µA @ -40 °C (-40 °F).
38 µA @ 0 °C (32 °F).
50 µA @ 100 °C (212 °F).
Power Supply: Provided by APT data acquisition box.
Long-Term Stability: 3000 hrs @ 20 °C (68 °F):
+0.018 °C (+ 0.03 °F) typical.
2000 hrs @ 70 °C (160 °F):
+0.07 °C (+ 0.126 °F) typical.
Housing: 1 1/2" nominal length, 3/16" O.D.
Lead Length: 10' 4 conductor flat phone cable.
Calibration Interval: 1 Yr. recommended (calibration adjustments are made using TECLOG channel Parameters).
Warranty 1 year.

Relative Humidity Sensor
Sensing Method: Thermostet Polymer based capacitance relative humidity sensor.
Accuracy: +/- 5% RH (0 to 60% RH),
+/- 8% RH at 90% RH (@ 25 °C, non-condensing).
Range: 0 to 100% RH.
Linearity: +/- 0.5% RH typical.
Repeatability: +/- 0.5% RH.
T90 Response Time: 30 seconds in slowly moving air typical.
Long-Term Stability: +/- 1% RH typical at 50% RH in 5 years.
Hysteresis: +/- 0.8% RH maximum (included in accuracy).
Temperature: Actual RH = Sensor RH / (1.093-.0012T) Compensation: where T=°F.
- Effect on Zero Shift: +/- 0.007% RH/°C (Negligible).
- Effect on Span: -0.22% RH/°C (<1% RH effect typical in occupied systems above 15 °C).
Operating Temperature: -40 to 85 °C (-40 to 185 °F).
Storage Temperature: -51 to 110 °C (-60 to 230 °F).
Output: 0.8 - 3.9 Vdcout (0 to 100%RH) for 5 Vdcsupply.
Current Draw: 200 µA typical @ 5 Vdc.
Power Supply: Provided by APT data acquisition box.
Housing: 2" nominal length, 5/16" O.D.
Lead Lengths: 10' 4 conductor flat phone cable.
Handling: Do not immerse in water or subject to prolonged condensation.
Calibration Interval: 1 Yr. recommended (calibration adjustments are made using TECLOG channel Parameters).
Warranty 1 year.

Carbon Monoxide Sensor
Sensing Method: Electrochemical (fuel cell).
Accuracy: +/- 5% of reading (@ 20 °C, 50% RH, 1013 mBar).
Range/Resolution: 0 - 2,000 ppm / 0.5 ppm.
Linearity: Linear (full range).
Repeatability: +/- 1% of signal.
T90 Response Time: < 30 seconds.
Long-Term Stability: < 2% of signal/month.
Temperature Effect on Span: 0.5%/°C typical, 0.75%/°C maximum.
Barometric Pressure Effect: 0.02% signal/mBar.
Maximum Zero Shift: 3 ppm (20 °C to 40 °C).
Typical Baseline Range: 0 +/- 0.5 ppm.
Operating Conditions:  
- Temperature -20 °C to 45 °C.
- RH 15 to 90%, non-condensing.
- Pressure Atmospheric +/- 10%.
Storage Temperature: 0 to 20 °C.
Output: 1mV/ppm.
Current Draw: 0.5 µA typical @ 5 Vdc.
Power Supply: Provided by APT data acquisition box.
Expected Operating Life: 2 years in air, minimum.
Housing: 3" x 2 1/2" x 1 1/2" anodized aluminum w/ RJ11 phone jack.
Lead Lengths: 10' 4 conductor flat phone cable.
Handling: Avoid condensing conditions and exposure to >2,000 ppm.
Calibration Interval: 6 months recommended (if CO sensor is being used for safety purposes, more frequent calibration checks may be desired).
Warranty 1 year.